Type | (Cust.) Art. no. | d | Mz | bar | i | CAD | Legend | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Type | SO 51124-1-M8x1 D | Art. no. | 058.1153.006 | d | 1.0 mm | Mz | M8x1 | bar | 250.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-1,5-M6x,75 D * | Art. no. | 058.1153.010 | d | 1.5 mm | Mz | M6x0.75 | bar | 250.0 bar | i | 5.5 mm | CAD | Download | |
Type | SO 51124-1,5-M8x1 D | Art. no. | 058.1153.011 | d | 1.5 mm | Mz | M8x1 | bar | 250.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-1,5-M10x1 D | Art. no. | 058.1153.012 | d | 1.5 mm | Mz | M10x1 | bar | 250.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-2-M8x1 D | Art. no. | 058.1153.035 | d | 2.0 mm | Mz | M8x1 | bar | 250.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-2,5-M8x1 D | Art. no. | 058.1153.043 | d | 2.5 mm | Mz | M8x1 | bar | 250.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-3-M8x1 D | Art. no. | 058.1153.060 | d | 3.0 mm | Mz | M8x1 | bar | 250.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-3-M10x1 D | Art. no. | 058.1153.065 | d | 3.0 mm | Mz | M10x1 | bar | 250.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-3,5-M8x1 D | Art. no. | 058.1153.068 | d | 3.5 mm | Mz | M8x1 | bar | 200.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-4-M8X1 D | Art. no. | 058.1153.090 | d | 4.0 mm | Mz | M8x1 | bar | 200.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-4-M10x1 D | Art. no. | 058.1153.096 | d | 4.0 mm | Mz | M10x1 | bar | 200.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-5-M10x1 D | Art. no. | 058.1153.135 | d | 5.0 mm | Mz | M10x1 | bar | 200.0 bar | i | 8.0 mm | CAD | Download | |
Type | SO 51124-6-M10x1 D | Art. no. | 058.1153.180 | d | 6.0 mm | Mz | M10x1 | bar | 200.0 bar | i | 8.0 mm | CAD | Download |
Temperature probe union METR
with edge seal and with stainless steel compression ferrule
SO Code:
-
Art. no.: -
Technical details
Additional information
Temperature up to +300°C
When mounted for the first time, the compression ferrule is pressed onto the tube by tightening the nut. A metal sealing is the result.
The union can be demounted by loosening the nut. However, the compression ferrule remains on the tube. A displacement of the tube is not possible after the first mounting.
For later displacement of the compression ferrule, the use of the temperature probe union with PTFE compression ferrule SO 51194-D-PTFE is recommended.
* For size M6x0.75 we recommend the use of the washer SO 40507.
If necessary, the relevant washer must be ordered separately.
When mounted for the first time, the compression ferrule is pressed onto the tube by tightening the nut. A metal sealing is the result.
The union can be demounted by loosening the nut. However, the compression ferrule remains on the tube. A displacement of the tube is not possible after the first mounting.
For later displacement of the compression ferrule, the use of the temperature probe union with PTFE compression ferrule SO 51194-D-PTFE is recommended.
* For size M6x0.75 we recommend the use of the washer SO 40507.
If necessary, the relevant washer must be ordered separately.
Temperature up to +300°C
When mounted for the first time, the compression ferrule is pressed onto the tube by tightening the nut. A metal sealing is the result.
The union can be demounted by loosening the nut. However, the compression ferrule remains on the tube. A displacement of the tube is not possible after the first mounting.
For later displacement of the compression ferrule, the use of the temperature probe union with PTFE compression ferrule SO 51194-D-PTFE is recommended.
* For size M6x0.75 we recommend the use of the washer SO 40507.
If necessary, the relevant washer must be ordered separately.
When mounted for the first time, the compression ferrule is pressed onto the tube by tightening the nut. A metal sealing is the result.
The union can be demounted by loosening the nut. However, the compression ferrule remains on the tube. A displacement of the tube is not possible after the first mounting.
For later displacement of the compression ferrule, the use of the temperature probe union with PTFE compression ferrule SO 51194-D-PTFE is recommended.
* For size M6x0.75 we recommend the use of the washer SO 40507.
If necessary, the relevant washer must be ordered separately.